Home / News & Resources / FAQs / Additional Installation Notes for Direct-Burial Tracer Wire

Additional Installation Notes for Direct-Burial Tracer Wire

Source: Hengtong Electric Published: 2022-07-01 0 views
Trace line "shall be laid together with PE pipe; Generally, metal wire cores are used to apply signals to the "metal wire" through the detection equipment, and the detection receiver receives the signals, so as to find the accurate position of the tracer wire, that is, synchronously track to the specific position of the PE gas pipeline; In order to facilitate the transformation and maintenance of PE pipes. The following are some supplements to the construction precautions of the tracer wire, which we briefly introduce to you as follows:
1, When using, pay attention to the setting out length of the tracer wire, and put as much as you use. You cannot pour out all the tracer wire at one time.
2, When the buried tracer wire enters the directional drilling hole with the pipe, it should be watched by someone to prevent the tracer wire from knotting or winding together.
Direct-Burial Tracer Wire
3, It's better to have a simple pay off rack, fix the tracer wire on the pay off rack, and let the tracer wire and the pipe drag at the same time.
4, In the process of dragging the pipe, the tracer wire shall not be tripped by small trees or other obstacles to avoid being broken.
5, The tracer wire and the top of the pipe should be tied firmly to prevent the tracer wire from falling off when the pipe crosses. If the tracer wire is to go out of the ground surface, a certain length should be reserved appropriately. It is suggested that the reserved length of the tracer wire after leaving the ground is about 1.5m for detection.
6, The tracer wire shall not have joints during the use of directional drilling.
7, In the construction of trenchless engineering, the buried tracer wire outside the PE pipe is easy to be broken during the dragging process. A simple way is to choose a conductor or steel wire rope with larger cross-sectional area and higher strength, or pre thread a tracer wire inside the pipe to avoid the breakage. Its detection effect is the same as that outside, but when doing so, the connection between the internal tracer wire head and the external tracer wire needs to be handled well.
Through the above article, you can clearly understand the content of the problem. I believe that after reading this article, you can have a more in-depth understanding of the product and the matter. In the future, if you want to know more relevant knowledge, you can continue to pay attention to our official website http://webtest2.daoshangbao.cn , please feel free to contact us if you need anything.