The warning tape is processed by anti-corrosion treatment. It has good corrosion resistance and bright and eye-catching color. It can be laid underground for many years for a long time, and the quality of long-term burial remains unchanged. How to use the warning tape?
1. Check whether the signal access point is reserved and whether the installation method is correct.
2. Check whether the conductive wire in the warning tape can load detection signals, whether there is signal leakage, and whether sufficient signal detection wells are set;
3. After the pipeline warning tape is installed, whether the beginning and end are isolated from the ground, and whether the warning tape in the signal detection well is fixed;

4. Does the diameter of the conductive wire in the warning tape meet the application requirements? If the diameter of the wire is too small, it is easy to be broken. If the diameter is too large, it will lead to large detection signal error. Therefore, the diameter with comprehensive effect should be selected. The main problem of the detection signal is that the signal continuity is easily affected. There are many reasons:
① It is possible that the wire inside the warning tape was broken due to the operation error during the construction, resulting in the detection short circuit
② The insulation and waterproof treatment of the warning tape of the pipeline are not qualified enough, resulting in the wire being affected by moisture and affecting the detection
③ The diameter of the conductive wire is too large, resulting in large resistance and signal attenuation, which affects the detection effect.
The use of pipeline warning tape shows the relevant content in four aspects. If you have any questions about this, you can come to our website at any time http://webtest2.daoshangbao.cn Consult and understand!